Hey Norton,
Older Romex was a two-wire system, meaning the Romex consisted of only two wires a hot and a neutral, but not a ground. The term open ground, just means that there is not a ground wire present. A hot and a neutral is all it takes to make the lights and the receptacles work. In the early sixties the electrical industry converted to Romex with a third wire, this wire was not intended to make the lights or receptacles work better, but to increase shock safety, by protecting equipment that is plugged in to the circuit against a ground fault. Electricity tries to find it’s way to ground, when it finds it’s way to the ground, that is called a ground fault, that’s how you get shocked. The electricity is using you to travel to the ground. The ground wire is just making an easer path for stray electricity to find ground instead of using you.
With a two-wire system (open ground system) like yours, replacing old receptacles in the bathrooms, kitchen, exterior, garage, and basement with GFCI (Ground Fault Circuit Interrupter) receptacles will increase safety. GFCI protection is a system that shuts off the power if it senses a ground fault, that means the electricity is passing thought you to the ground. The GFCI’s are not designed to protect equipment, but to protect you against electrocution.
Consult an Electrician about the best way to add the GFCI protection in your specific situation.
Thanks for your question.
Please send questions to agarrett54@hotmail.com Please put "Hey Al" in the subject box.