During most real estate transactions, time is an important factor. Most decisions are made during the time restrictions of the parties involved. It is important, due to these constraints, that parties have the best data available when making decisions.
Radon tests done by a qualified tester,using a Femto-TECH CRM-510 Continuous Radon Monitor with high sensitivity provides the greatest amount of information and data for decision making. The EPA recommends when doing a Radon test involving a real estate transaction, that not only the Radon be measured, but also that humidity, temperature, barometric pressure and tamper resistance be logged. This helps in assuring proper testing conditions are met. The femto-TECH, CRM-510 meets or exceeds these guide-lines and is an EPA listed and approved instrument of the highest quality. Best of all, the results of the test can be printed directly after the conclusion of the test. There is no waiting for samples to be sent off to a lab for analysis.
When having a radon test done that involves a real estate transaction, it is essential that all EPA guidelines and standard protocols are followed.
• Closed house conditions must be maintained for 12 hours before the start of the test and for the test duration. Close all windows and doors and keep them closed during the test period. Doors can only be opened and closed to enter and leave the premises, but windows will need to be kept closed. Overhead garage doors need to be closed except for entry and exit of a vehicle.
• Minimize operation of bathroom or kitchen exhaust fans or non-essential exhaust appliances.
• Do not operate fireplaces, ceiling fans, whole house attic fans, electrostatic precipitators, window air conditioners, or any other external-Central heating and cooling systems can be operated as normal.
• The radon testing device cannot be tampered with or moved during the test.
• The testing device placement shall be in the lowest area deemed livable in the structure. Device placement shall be a minimum of 20 inches above the floor and no higher that 8 feet, and away from outside door and window openings.
• Tests should not be conducted during extreme weather conditions.
The above steps are designed to give uniformity to the test data when making decisions with reference to the EPA radon action level of 4.0 pCi/l.